PCXX-30/115AC
PCX-30/115AC Operating Ratings |
Ibex Battery Systems |
AC Line Voltage Isolation from Ground (note 1) Output Short Circuit Duration AC Line Frequency (Min. & Max.) Operating Temperature Storage Temperature MTBF (Calculated) |
108/216VAC - 126.5/253VAC 150V peak Continuous 50Hz - 60Hz -40C to +85C -55C to +105C 150,000 Hours (25C) | Block Diagram Operation Manual General Description Mechanical Info. | |
Electrical characteristics Unless stated otherwise, these specifications are valid over the operating temperature range. |
Parameter | Conditions | Minimum | Maximum | Units |
Max. Output Current (Note 2) | Each output | 3.0 | 3.5 | A |
Min. Load Current (Note 3) | Each output | 15 | - | mA |
Output Ripple & Noise (Note 4) | Before extra filtering | - | 100 | mV pk-pk |
Output Ripple & Noise | After extra filtering | - | 20 | mV pk-pk |
Output Regulation (Note 5) | V1A and V2A | - | +/- 2% | - |
Note 1: Between the board's output terminals and ground.
Note 2: The regulator circuit automatically limits the output current to Note 3: A minimum load current of 15mA is required to maintain regulation. Note 4: There is an extra-filtered output available for each voltage. The resistance of the filter is approximately 0.05 ohms which gives the choice between lower ripple and tighter regulation. Note 5: At the V1A and V2A ports. Under all conditions of line, load, and ambient temperature. V1B and V2B ports have an additional voltage sag of approximately 50mV per ampere of output current. |
low temperature 18v power supply supplies, high temperature 18v power supply supplies, low temp 18v power supply supplies, high temp 18v power supply supplies, wide temperature 18v power supply supplies, wide temp 18v power supply supplies, extreme temperature 18v power supply supplies, extreme temp 18v power supply supplies, extreme environment 18v power supply supplies |